Performance evaluation of pico hydroelectric generator as an alternative power source at Sitio San Juan, Buliwao, Quezon, Nueva Vizcaya/ (Record no. 692)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 01683nam a22001937a 4500 |
| 003 - CONTROL NUMBER IDENTIFIER | |
| control field | OSt |
| 005 - DATE AND TIME OF LATEST TRANSACTION | |
| control field | 20250402084717.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
| fixed length control field | 250402b |||||||| |||| 00| 0 eng d |
| 040 ## - CATALOGING SOURCE | |
| Transcribing agency | NVSU |
| 100 ## - MAIN ENTRY--PERSONAL NAME | |
| Personal name | Cabudol, Mark Lester B. |
| 245 ## - TITLE STATEMENT | |
| Title | Performance evaluation of pico hydroelectric generator as an alternative power source at Sitio San Juan, Buliwao, Quezon, Nueva Vizcaya/ |
| Statement of responsibility, etc. | Mark Lester B. Cabudol and Dyna Kei Donato |
| 260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
| Place of publication, distribution, etc. | Bayombong: |
| Name of publisher, distributor, etc. | Nueva Vizcaya State University, |
| Date of publication, distribution, etc. | 2024. |
| 300 ## - PHYSICAL DESCRIPTION | |
| Extent | xiv, 48 leaves : |
| Other physical details | illustrations (some colored), photos ; |
| Dimensions | 28 cm. |
| 500 ## - GENERAL NOTE | |
| General note | The researchers conducted a performance evaluation of the Pico hydroelectric generator. The generator's performance was evaluated in terms of theoretical power, actual power, and system efficiency. It was analyzed using Linear Regression at 100% level of significance using Statistical Package for the Social Sciences (SPSS) Test.<br/> <br/>Results showed that the system efficiency is directly proportional to the actual power produced by the generator. In addition there are factors to consider when achieving the desired system efficiency of the generator these are, voltage output of the car battery, loads used, and time for the load to discharge the car battery. Moreover, the highest system efficiency at 48.94% was achieved with the total load of 110 watts. Additionally, the payback period attained at 0.61 years with 26,491.62 Net Income. |
| 500 ## - GENERAL NOTE | |
| General note | Thesis (Bachelor of Science in Agricultural and Biosystems Engineering - AB Structure and Environmental Engineering) |
| 504 ## - BIBLIOGRAPHY, ETC. NOTE | |
| Bibliography, etc. note | Includes bibliographical references and appendices |
| 700 ## - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Donato, Dyna Kei, author. |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
| Source of classification or shelving scheme | Dewey Decimal Classification |
| Koha item type | Undergraduate Research |
| Suppress in OPAC | No |
| Withdrawn status | Lost status | Source of classification or shelving scheme | Damaged status | Not for loan | Home library | Current library | Shelving location | Date acquired | Source of acquisition | Total checkouts | Full call number | Barcode | Date last seen | Price effective from | Koha item type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Dewey Decimal Classification | Nueva Vizcaya State University - Bayombong Campus | Nueva Vizcaya State University - Bayombong Campus | General Reference Section | 04/02/2025 | Donation | U (BSABE) C117p 2024 | U2384 | 04/02/2025 | 04/02/2025 | Undergraduate Research |