<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>01683nam a22001937a 4500</leader>
  <controlfield tag="003">OSt</controlfield>
  <controlfield tag="005">20250402084717.0</controlfield>
  <controlfield tag="008">250402b        |||||||| |||| 00| 0 eng d</controlfield>
  <datafield tag="040" ind1=" " ind2=" ">
    <subfield code="c">NVSU</subfield>
  </datafield>
  <datafield tag="100" ind1=" " ind2=" ">
    <subfield code="a">Cabudol, Mark Lester B.</subfield>
  </datafield>
  <datafield tag="245" ind1=" " ind2=" ">
    <subfield code="a">Performance evaluation of pico hydroelectric generator as an alternative  power source at Sitio San Juan, Buliwao, Quezon, Nueva Vizcaya/</subfield>
    <subfield code="c">Mark Lester B. Cabudol and Dyna Kei Donato</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="a">Bayombong:</subfield>
    <subfield code="b">Nueva Vizcaya State University,</subfield>
    <subfield code="c">2024.</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">xiv, 48 leaves :</subfield>
    <subfield code="b">illustrations (some colored), photos ;</subfield>
    <subfield code="c">28 cm.</subfield>
  </datafield>
  <datafield tag="500" ind1=" " ind2=" ">
    <subfield code="a">The researchers conducted a performance evaluation of the Pico hydroelectric generator. The generator's performance was evaluated in terms of theoretical power, actual power, and system efficiency. It was analyzed using Linear Regression at 100% level of significance using Statistical Package for the Social Sciences (SPSS) Test.
 
Results showed that the system efficiency is directly proportional to the actual power produced by the generator. In addition there are factors to consider when achieving the desired system efficiency of the generator these are, voltage output of the car battery, loads used, and time for the load to discharge the car battery. Moreover, the highest system efficiency at 48.94% was achieved with the total load of 110 watts. Additionally, the payback period attained at 0.61 years with 26,491.62 Net Income.</subfield>
  </datafield>
  <datafield tag="500" ind1=" " ind2=" ">
    <subfield code="a">Thesis (Bachelor of Science in Agricultural and Biosystems Engineering - AB Structure and Environmental Engineering)</subfield>
  </datafield>
  <datafield tag="504" ind1=" " ind2=" ">
    <subfield code="a">Includes bibliographical references and appendices</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Donato, Dyna Kei, author.</subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="2">ddc</subfield>
    <subfield code="c">U</subfield>
    <subfield code="n">0</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="c">692</subfield>
    <subfield code="d">692</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="2">ddc</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="a">NVSUBAY</subfield>
    <subfield code="b">NVSUBAY</subfield>
    <subfield code="c">GR</subfield>
    <subfield code="d">2025-04-02</subfield>
    <subfield code="e">Donation</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">U (BSABE) C117p 2024</subfield>
    <subfield code="p">U2384</subfield>
    <subfield code="r">2025-04-02 08:47:51</subfield>
    <subfield code="w">2025-04-02</subfield>
    <subfield code="y">U</subfield>
  </datafield>
</record>