<?xml version="1.0" encoding="UTF-8"?>
<mods xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" version="3.1" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
  <titleInfo>
    <title>Design, fabrication and performance evaluation of small wind pump</title>
  </titleInfo>
  <name type="personal">
    <namePart>Bassi, Rhina Mae B.</namePart>
    <role>
      <roleTerm authority="marcrelator" type="text">creator</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Binalgan, Merlie Petsie A., author.</namePart>
  </name>
  <name type="personal">
    <namePart>De Guzman, Patrissa Marie M., author.</namePart>
  </name>
  <name type="personal">
    <namePart>Marcos, Ruby D., author.</namePart>
  </name>
  <name type="personal">
    <namePart>Rosario, Love Joy P., author.</namePart>
  </name>
  <typeOfResource>text</typeOfResource>
  <originInfo>
    <place>
      <placeTerm type="text">Bayombong</placeTerm>
    </place>
    <publisher>Nueva Vizcaya State University</publisher>
    <dateIssued>2023</dateIssued>
    <issuance>monographic</issuance>
  </originInfo>
  <language>
    <languageTerm authority="iso639-2b" type="code">eng</languageTerm>
  </language>
  <physicalDescription>
    <form authority="marcform">print</form>
    <extent>xvi, 84 leaves : illustrations (some colored), photos ; 28 cm.</extent>
  </physicalDescription>
  <note type="statement of responsibility">Rhina Mae B. Bassi, Merlie Petsie A. Binalgan, Patrissa Marie M. De Guzman, Ruby D. Marcos and Love Joy P. Rosario</note>
  <note>	Energy demand for water pumping has been growing in the country. A wind pump is designed and fabricated to lift irrigation water. The performance of the wind pump was evaluated in terms of water discharge, actual power generated, and efficiency. Regression analysis and coefficient of determination were used to determine the goodness of fit pump performance. 
	Results showed that 0.3 m/s was the initial wind speed to rotate the wind pump and lift water. Moreover, as wind speed increases the rotation, water discharge and actual power generated also increases. The lowest wind pump discharge and efficiency was 0.95 L/min and 20.56% and the highest wind pump discharge and efficiency was 5.45 L/min and 5.57%. This shows that the wind pump is efficient at low-wind speed. Additionally, the pumping capacity of the wind pump was 0. 33 m³/hr with a cost of Php 138.37/m³ higher than the water rate of Nueva Vizcaya this is cause by variability of wind. The return of investment of the water cost was used with 100.66 % and a payback period of 0.99 months.</note>
  <note>Thesis (Bachelor of Science in Agricultural and Biosystems Engineering - AB Machinery and Power Engineering)</note>
  <note>Includes bibliographical references and appendices </note>
  <recordInfo>
    <recordContentSource authority="marcorg"/>
    <recordCreationDate encoding="marc">250331</recordCreationDate>
    <recordChangeDate encoding="iso8601">20250331163458.0</recordChangeDate>
  </recordInfo>
</mods>