<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>02148nam a22002177a 4500</leader>
  <controlfield tag="003">OSt</controlfield>
  <controlfield tag="005">20250328114046.0</controlfield>
  <controlfield tag="008">250328b        |||||||| |||| 00| 0 eng d</controlfield>
  <datafield tag="040" ind1=" " ind2=" ">
    <subfield code="c">NVSU</subfield>
  </datafield>
  <datafield tag="100" ind1=" " ind2=" ">
    <subfield code="a">Antonio, Peejay Nathan Joy D.</subfield>
  </datafield>
  <datafield tag="245" ind1=" " ind2=" ">
    <subfield code="a">Utilization of cracked and pulverized waste glass in the production of concrete mixture as a partial replacement of sand/</subfield>
    <subfield code="c">Peejay Nathan Joy D. Antonio, Jason A. Bote, Roger M. Bricenio Jr. and Lyndon John A. Cadiz</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="a">Bayombong:</subfield>
    <subfield code="b">Nueva Vizcaya State University,</subfield>
    <subfield code="c">2023.</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">xi, 43 leaves :</subfield>
    <subfield code="b">illustrations, photos ;</subfield>
    <subfield code="c">28 cm.</subfield>
  </datafield>
  <datafield tag="500" ind1=" " ind2=" ">
    <subfield code="a">	This thesis investigates the effects on the compressive strength of concrete using cracked and pulverized clear bottles as partial sand replacement. Four samples were prepared and tested. MPO is the control batch which does not contain pulverized glass bottle. The other batches were MP25, MP50 and MP75 which contains 25%, 50% and 75% by volume of sand replaced. The results reveal that as the percentage of sand replacement increases, the average compressive strength tends to decrease. MP25 demonstrates a slightly higher average compressive strength of 6.77 MPa compared to MPO with no sand replacement with a compressive strength of 6.07 MPa. However, MP50 has an average compressive strength of only 3.73 which is a significant decrease in value compared to both MP0 and MP25. MP75 exhibits an average compressive strength of 5.70 MPa which is between that of MP25 and MP50. These findings indicate that while a small amount of replacement material can positively affect compressive strength, a higher percentage of replacement tends to result in a decrease in strength. Therefore, careful consideration should be given to selecting the appropriate replacement percentage to achieve the desired compressive strength in practical applications.</subfield>
  </datafield>
  <datafield tag="500" ind1=" " ind2=" ">
    <subfield code="a">Research paper (Bachelor of Science in Civil Engineering)</subfield>
  </datafield>
  <datafield tag="504" ind1=" " ind2=" ">
    <subfield code="a">Includes bibliographical references and appendices </subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Bote, Jason A., author.</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Bricenio Jr., Roger M., author.</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Cadiz, Lyndon John A., author.</subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="2">ddc</subfield>
    <subfield code="c">U</subfield>
    <subfield code="n">0</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="c">443</subfield>
    <subfield code="d">443</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="2">ddc</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="a">NVSUBAY</subfield>
    <subfield code="b">NVSUBAY</subfield>
    <subfield code="c">GR</subfield>
    <subfield code="d">2025-03-28</subfield>
    <subfield code="e">Donation</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">U (BSCE) An635u 2023</subfield>
    <subfield code="p">U2078</subfield>
    <subfield code="r">2025-03-28 11:41:33</subfield>
    <subfield code="w">2025-03-28</subfield>
    <subfield code="y">U</subfield>
  </datafield>
</record>
