<?xml version="1.0" encoding="UTF-8"?>
<mods xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" version="3.1" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
  <titleInfo>
    <title>Vertical agriculture for cooling buildings</title>
  </titleInfo>
  <name type="personal">
    <namePart>Sapi-il, Ralf B.</namePart>
    <role>
      <roleTerm authority="marcrelator" type="text">creator</roleTerm>
    </role>
  </name>
  <typeOfResource>text</typeOfResource>
  <originInfo>
    <place>
      <placeTerm type="text">Bayombong</placeTerm>
    </place>
    <publisher>Nueva Vizcaya State University</publisher>
    <dateIssued>2024</dateIssued>
    <issuance>monographic</issuance>
  </originInfo>
  <language>
    <languageTerm authority="iso639-2b" type="code">eng</languageTerm>
  </language>
  <physicalDescription>
    <form authority="marcform">print</form>
    <extent>xiv, 57 leaves : illustrations, photos ; 28 cm.</extent>
  </physicalDescription>
  <note type="statement of responsibility">Ralf B. Sapi-il</note>
  <note>The Vertical Agriculture for Cooling Buildings setup was conducted at the barangay hall of Socbot, Pinukpuk, Kalinga from August to October 2023. This study generally aimed to reduce temperature over a large area with the use of vertical hydroponics agriculture. The building was divided into two, one room where the setup was installed and the other room for a completely normal room. The setup has a height of 2.75m and 16m in length covering the outer wall and compares the heat transfer between the two rooms. Statistical analysis revealed a significant difference in ambient temperatures between the rooms, with the room without the setup averaging 32.29 deg * C and the room with the setup averaging 29.32 deg * C The setup led to decreases of 6.03 deg * C in ambient temperature, 7.62 deg * C in outside wall temperature, 5.57 deg * C in inside wall temperature, and a reduction in heat transfer of 4.19. The thermal conductivity of the setup was calculated at 7.06 * 10 ^ - 3 * K / W and the cooling efficiency was measured at 51.48%, highlighting the effectiveness of the hydroponics setup in reducing temperatures. Simple randomized survey was conducted to determine the acceptability of the set-up that yielded to the substantial positive responses (extremely favorable and favorable) which is 55% of the respondents suggest potential interest or openness to adopting vertical hydroponics for cooling purposes. The Simple Economic Analysis resulted in a Return on Investment (ROI) of 239.70% and a Payback Period (PB) of only 5 months, highlighting both impressive profitability and a swift financial recovery. The integration of the hydroponics set-up led to substantial reductions in both the exterior and interior wall temperatures including the ambient temperature, contributing to a cooler indoor environment for human comfort.

Keywords: cooling system, wall hydroponics, vertical agriculture
</note>
  <note>Thesis (Master of Science in Agricultural Engineering - Soil and Water Management)</note>
  <note>Includes appendices and bibliographical references.</note>
  <recordInfo>
    <recordContentSource authority="marcorg"/>
    <recordCreationDate encoding="marc">250327</recordCreationDate>
    <recordChangeDate encoding="iso8601">20250327105512.0</recordChangeDate>
  </recordInfo>
</mods>