<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>02537nam a22001817a 4500</leader>
  <controlfield tag="003">OSt</controlfield>
  <controlfield tag="005">20250327105512.0</controlfield>
  <controlfield tag="008">250327b        |||||||| |||| 00| 0 eng d</controlfield>
  <datafield tag="040" ind1=" " ind2=" ">
    <subfield code="c">NVSU</subfield>
  </datafield>
  <datafield tag="100" ind1=" " ind2=" ">
    <subfield code="a">Sapi-il, Ralf B.</subfield>
  </datafield>
  <datafield tag="245" ind1=" " ind2=" ">
    <subfield code="a">Vertical agriculture for cooling buildings/</subfield>
    <subfield code="c">Ralf B. Sapi-il</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="a">Bayombong:</subfield>
    <subfield code="b">Nueva Vizcaya State University,</subfield>
    <subfield code="c">2024.</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">xiv, 57 leaves :</subfield>
    <subfield code="b">illustrations, photos ;</subfield>
    <subfield code="c">28 cm.</subfield>
  </datafield>
  <datafield tag="500" ind1=" " ind2=" ">
    <subfield code="a">The Vertical Agriculture for Cooling Buildings setup was conducted at the barangay hall of Socbot, Pinukpuk, Kalinga from August to October 2023. This study generally aimed to reduce temperature over a large area with the use of vertical hydroponics agriculture. The building was divided into two, one room where the setup was installed and the other room for a completely normal room. The setup has a height of 2.75m and 16m in length covering the outer wall and compares the heat transfer between the two rooms. Statistical analysis revealed a significant difference in ambient temperatures between the rooms, with the room without the setup averaging 32.29 deg * C and the room with the setup averaging 29.32 deg * C The setup led to decreases of 6.03 deg * C in ambient temperature, 7.62 deg * C in outside wall temperature, 5.57 deg * C in inside wall temperature, and a reduction in heat transfer of 4.19. The thermal conductivity of the setup was calculated at 7.06 * 10 ^ - 3 * K / W and the cooling efficiency was measured at 51.48%, highlighting the effectiveness of the hydroponics setup in reducing temperatures. Simple randomized survey was conducted to determine the acceptability of the set-up that yielded to the substantial positive responses (extremely favorable and favorable) which is 55% of the respondents suggest potential interest or openness to adopting vertical hydroponics for cooling purposes. The Simple Economic Analysis resulted in a Return on Investment (ROI) of 239.70% and a Payback Period (PB) of only 5 months, highlighting both impressive profitability and a swift financial recovery. The integration of the hydroponics set-up led to substantial reductions in both the exterior and interior wall temperatures including the ambient temperature, contributing to a cooler indoor environment for human comfort.

Keywords: cooling system, wall hydroponics, vertical agriculture
</subfield>
  </datafield>
  <datafield tag="500" ind1=" " ind2=" ">
    <subfield code="a">Thesis (Master of Science in Agricultural Engineering - Soil and Water Management)</subfield>
  </datafield>
  <datafield tag="504" ind1=" " ind2=" ">
    <subfield code="a">Includes appendices and bibliographical references.</subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="2">ddc</subfield>
    <subfield code="c">TH</subfield>
    <subfield code="n">0</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="c">413</subfield>
    <subfield code="d">413</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="2">ddc</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="a">NVSUBAY</subfield>
    <subfield code="b">NVSUBAY</subfield>
    <subfield code="c">GS</subfield>
    <subfield code="d">2025-03-27</subfield>
    <subfield code="e">Donation</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">T Sa241v 2024</subfield>
    <subfield code="p">T1116</subfield>
    <subfield code="r">2025-03-27 10:55:52</subfield>
    <subfield code="w">2025-03-27</subfield>
    <subfield code="y">TH</subfield>
  </datafield>
</record>
