Design, fabrication and performance evaluation of small wind pump (Record no. 677)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 02040nam a22002297a 4500 |
| 003 - CONTROL NUMBER IDENTIFIER | |
| control field | OSt |
| 005 - DATE AND TIME OF LATEST TRANSACTION | |
| control field | 20250331163458.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
| fixed length control field | 250331b |||||||| |||| 00| 0 eng d |
| 040 ## - CATALOGING SOURCE | |
| Transcribing agency | NVSU |
| 100 ## - MAIN ENTRY--PERSONAL NAME | |
| Personal name | Bassi, Rhina Mae B. |
| 245 ## - TITLE STATEMENT | |
| Title | Design, fabrication and performance evaluation of small wind pump |
| Statement of responsibility, etc. | Rhina Mae B. Bassi, Merlie Petsie A. Binalgan, Patrissa Marie M. De Guzman, Ruby D. Marcos and Love Joy P. Rosario |
| 260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
| Place of publication, distribution, etc. | Bayombong: |
| Name of publisher, distributor, etc. | Nueva Vizcaya State University |
| Date of publication, distribution, etc. | 2023. |
| 300 ## - PHYSICAL DESCRIPTION | |
| Extent | xvi, 84 leaves : |
| Other physical details | illustrations (some colored), photos ; |
| Dimensions | 28 cm. |
| 500 ## - GENERAL NOTE | |
| General note | Energy demand for water pumping has been growing in the country. A wind pump is designed and fabricated to lift irrigation water. The performance of the wind pump was evaluated in terms of water discharge, actual power generated, and efficiency. Regression analysis and coefficient of determination were used to determine the goodness of fit pump performance. <br/> Results showed that 0.3 m/s was the initial wind speed to rotate the wind pump and lift water. Moreover, as wind speed increases the rotation, water discharge and actual power generated also increases. The lowest wind pump discharge and efficiency was 0.95 L/min and 20.56% and the highest wind pump discharge and efficiency was 5.45 L/min and 5.57%. This shows that the wind pump is efficient at low-wind speed. Additionally, the pumping capacity of the wind pump was 0. 33 m³/hr with a cost of Php 138.37/m³ higher than the water rate of Nueva Vizcaya this is cause by variability of wind. The return of investment of the water cost was used with 100.66 % and a payback period of 0.99 months. |
| 500 ## - GENERAL NOTE | |
| General note | Thesis (Bachelor of Science in Agricultural and Biosystems Engineering - AB Machinery and Power Engineering) |
| 504 ## - BIBLIOGRAPHY, ETC. NOTE | |
| Bibliography, etc. note | Includes bibliographical references and appendices |
| 700 ## - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Binalgan, Merlie Petsie A., author. |
| 700 ## - ADDED ENTRY--PERSONAL NAME | |
| Personal name | De Guzman, Patrissa Marie M., author. |
| 700 ## - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Marcos, Ruby D., author. |
| 700 ## - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Rosario, Love Joy P., author. |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
| Source of classification or shelving scheme | Dewey Decimal Classification |
| Koha item type | Undergraduate Research |
| Suppress in OPAC | No |
| Withdrawn status | Lost status | Source of classification or shelving scheme | Damaged status | Not for loan | Home library | Current library | Shelving location | Date acquired | Source of acquisition | Total checkouts | Full call number | Barcode | Date last seen | Price effective from | Koha item type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Dewey Decimal Classification | Nueva Vizcaya State University - Bayombong Campus | Nueva Vizcaya State University - Bayombong Campus | General Reference Section | 03/31/2025 | Donation | U (BSABE) B321d 2023 | U2188 | 03/31/2025 | 03/31/2025 | Undergraduate Research |