Vertical agriculture for cooling buildings/ (Record no. 413)

MARC details
000 -LEADER
fixed length control field 02537nam a22001817a 4500
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250327105512.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 250327b |||||||| |||| 00| 0 eng d
040 ## - CATALOGING SOURCE
Transcribing agency NVSU
100 ## - MAIN ENTRY--PERSONAL NAME
Personal name Sapi-il, Ralf B.
245 ## - TITLE STATEMENT
Title Vertical agriculture for cooling buildings/
Statement of responsibility, etc. Ralf B. Sapi-il
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Bayombong:
Name of publisher, distributor, etc. Nueva Vizcaya State University,
Date of publication, distribution, etc. 2024.
300 ## - PHYSICAL DESCRIPTION
Extent xiv, 57 leaves :
Other physical details illustrations, photos ;
Dimensions 28 cm.
500 ## - GENERAL NOTE
General note The Vertical Agriculture for Cooling Buildings setup was conducted at the barangay hall of Socbot, Pinukpuk, Kalinga from August to October 2023. This study generally aimed to reduce temperature over a large area with the use of vertical hydroponics agriculture. The building was divided into two, one room where the setup was installed and the other room for a completely normal room. The setup has a height of 2.75m and 16m in length covering the outer wall and compares the heat transfer between the two rooms. Statistical analysis revealed a significant difference in ambient temperatures between the rooms, with the room without the setup averaging 32.29 deg * C and the room with the setup averaging 29.32 deg * C The setup led to decreases of 6.03 deg * C in ambient temperature, 7.62 deg * C in outside wall temperature, 5.57 deg * C in inside wall temperature, and a reduction in heat transfer of 4.19. The thermal conductivity of the setup was calculated at 7.06 * 10 ^ - 3 * K / W and the cooling efficiency was measured at 51.48%, highlighting the effectiveness of the hydroponics setup in reducing temperatures. Simple randomized survey was conducted to determine the acceptability of the set-up that yielded to the substantial positive responses (extremely favorable and favorable) which is 55% of the respondents suggest potential interest or openness to adopting vertical hydroponics for cooling purposes. The Simple Economic Analysis resulted in a Return on Investment (ROI) of 239.70% and a Payback Period (PB) of only 5 months, highlighting both impressive profitability and a swift financial recovery. The integration of the hydroponics set-up led to substantial reductions in both the exterior and interior wall temperatures including the ambient temperature, contributing to a cooler indoor environment for human comfort.<br/><br/>Keywords: cooling system, wall hydroponics, vertical agriculture<br/>
500 ## - GENERAL NOTE
General note Thesis (Master of Science in Agricultural Engineering - Soil and Water Management)
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Includes appendices and bibliographical references.
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Suppress in OPAC No
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Home library Current library Shelving location Date acquired Source of acquisition Total checkouts Full call number Barcode Date last seen Price effective from Koha item type
    Dewey Decimal Classification     Nueva Vizcaya State University - Bayombong Campus Nueva Vizcaya State University - Bayombong Campus Graduate School Section 03/27/2025 Donation   T Sa241v 2024 T1116 03/27/2025 03/27/2025 Thesis

NUEVA VIZCAYA STATE UNIVERSITY

A leading University in education, innovation and sustainable development

@2024 NVSU | Powered by : Koha